Egypt published standard for Injection containers and accessories, Indelible ink, Flexographic inks & Plywood Egyptian Organization for Standardization and Quality published following standards Injection containers and accessories — Part 1: Injection vials made of glass tubing" Standard specifies the form, dimensions and capacities of glass vials for injectable preparations.It also specifies the material from which such containers shall be made and the performance requirements of those containers.Worth mentioning is that this draft standard is technically identical with ISO 8362-1/2018 Click here for notification Indelible ink (election ink) Standard specifies the requirements and methods of sampling and test for indelible ink used for marking voter's fingers with a suitable applicator. Worth mentioning is that this draft standard is technically identical with IS 13209/1991 Click here for notification Flexographic inks Standard specifies the requirements and methods of sampling and test for flexographic inks water or solvent base used for printing of different purposes. Worth mentioning is that this draft standard has been formulated according to National studies. Click here for notification ES 8284-2 for "Outdoor furniture - seating and tables for camping, domestic and contract use -- part 2: mechanical safety requirements and test methods for seating" Standard specifies the minimum requirements for the safety, strength and durability of all types of outdoor seating for adults, without regard to materials, design/construction or manufacturing processes. Worth mentioning is that this draft standard is technically identical with EN 581-2:2015/AC:2016 Click here for notification ES 3241-2 "Injection equipment for medical use Standard specifies materials, dimensions, capacities, performance and packaging requirements for three forms of glass ampoule (forms B, C and D) for injectable pharmaceutical products. It is applicable to ampoules with and without a colour break-ring; the provision of ampoules with a colour ,break-ring, and the choice of colour of the break-ring, is subject to agreement between the manufacturer and user. Ampoules complying with this part of ISO 9187 are intended for single use only. Worth mentioning is that this standard is technically identical with ISO 9187-2/2010 (confirmed in 2015) Click here for notification ES 3241-1 for "Injection equipment for medical use Standard specifies materials, dimensions, capacities, performance and packaging requirements for three forms of glass ampoule (forms B, C and D) for injectable pharmaceutical products. It is applicable to ampoules with and without a colour break-ring; the provision of ampoules with a colour ,break-ring, and the choice of colour of the break-ring, is subject to agreement between the manufacturer and user. Ampoules complying with this part of ISO 9187 are intended for single use only. Worth mentioning is that this draft standard is technically identical with ISO 9187-1/2010 (confirmed in 2015) Click here for notification ES 2799-2 for "Plywood used in concrete shuttering works - Part 2: Test methods Standard specifies the tests that determine the degree of quality for Plywood used in concrete shuttering works. Worth mentioning is that this draft standard is technically identical with IS 4990/2011 Click here for notification ES 2799-1 for "Plywood used in concrete shuttering works Standard specifies requirements for the plywood used in pouring concrete, which is known as the plywood used in concrete shuttering treated with preservative material and is especially suitable for use in concrete shuttering and form works. Click here for notification ES 446-4 for "Containers and accessories for pharmaceutical preparations Standard specifies the design, dimensions, material and requirements of tablet glass bottles. Tablet glass bottles are applicable to primary packs used in direct contact with a drug. Worth mentioning is that this draft standard is technically identical with ISO 11418-4/2005 (confirmed in 2019) Click here for notification ES 445-2 for "Containers and accessories for pharmaceutical preparations Standard specifies the design, dimensions, material and requirements of screw-neck glass bottles for pharmaceutical preparations in liquid form (syrups). Screw-neck glass bottles are applicable to primary packs used in direct contact with a drug. This document is applicable to screw-neck glass bottles used in pharmacy. Together with the corresponding closure systems, they serve for packaging of pharmaceutical preparations, which are not intended for parenteral use. Worth mentioning is that this draft standard is technically identical Click here for notification Products covered: Transfusion, infusion and injection equipment, Injection containers and accessories, Indelible ink, Flexographic inks & Plywood HS Code: 9018, 321590, 4412 Proposed date of adoption:To be determined Proposed date of entry into force:To be determined Final date for comments:60 days from notification |